Product description
- Radiofrequency electrocautery, ideal for micro coagulation interventions and for small and medium surgery, either monopolar or bipolar.
- Pure cuts, cuts with coagulation and bipolar coagulation can be performed using a special adapter.
- Thanks to the digital readout of the power supplied, the applications of this instrument are safe and highly reproducible.
- SURTRON 80-120-160 allows highly professional surgery thanks to its ergonomic and safe design.
- The connection to the neutral reference electrode offers constant monitoring.
- The possibility of switching functions and control the power output through the electrode holder handpiece allow to carry out the surgery without having to concentrate on anything but the operative field.
Use in bipolar mode:
To use the machine in bipolar mode, the following items must be purchased:
- Adapter for bipolar function (Ref. 138-00498-00)
- Silicone cable for bipolar electrocautery (Ref. 138-CB462)
- Bipolar electrodes or forceps (see optional accessories)
Applications:
Description | Q80 188-QUI10100101 | Q120 188-QUI10100201 | Q160 188-QUI10100301 |
Medical consultation surgery | Recommended | Recommended | Recommended |
Pediatric surgery | Not recommended | Not recommended | Suitable |
Plastic surgery | Not recommended | Not recommended | Suitable |
Vascular surgery | Suitable | Recommended | Recommended |
Dental | Recommended | Suitable | Not recommended |
Dermatology | Recommended | Recommended | Recommended |
Endoscopy | Not recommended | Not recommended | Suitable |
Gynecology | Not recommended | Suitable | Recommended |
Gastroenterology | Not recommended | Not recommended | Suitable |
Neurosurgery | Not recommended | Not recommended | Suitable |
Orthopedics | Not recommended | Not recommended | Suitable |
Otolaryngology | Not recommended | Suitable | Recommended |
Pneumology | Not recommended | Not recommended | Suitable |
Emergency | Suitable | Recommended | Recommended |
Urology | Not recommended | Not recommended | Suitable |
Veterinary | Suitable | Recommended | Recommended |
Controls:
- Control circuit/patient OC board.
- Control of the radiated power.
- Self diagnosis.
Technical features:
- Working frequency: 600 kHz
- Neutral electrodes: F
- Voltage: 115 -230 VAC
- Line frequency: 50-60 Hz
- Unit weight: 5 Kg
- Unit dimensions: 104 x 254 x 288 mm
SURTRON | 80 | 120 | 160 |
Maximum power cutting CUT | 80 W | 120 W | 160 W |
Maximum power cutting / coagulation BLEND | 60 W | 90 W | 120 W |
Maximum power coagulation COAG FORCED | 50 W | 80 W | 100 W |
Maximum power coagulation SOFT COAG | 40 W | 60 W | 80 W |
Maximum power bipolar coagulation BIPOLAR COAG | 30 W | 40 W | 60 W |
Maximum power consumption | 230 VA | 300 VA | 350 VA |
Included accessories:
- Power cable
- Footswitch
- Cable for patient plate (ref. 138-00404.08)
- Kit autoclavable electrodes (10 pcs)
- Reusable metal patient plate (ref. 138-5365A)
- Reusable handle with buttons
Certification:
- EC Directive 93/42 Medical Devices.
Optional accessories:
- 138-00500.00: Kit 10 assorted electrodes 5 cm (L1,L2,L3,L4,L5,L6,L7,L8,L9 and L10)
- 138-152-110: reusable blade electrode length 7 cm D02 model
- 138-152-112: reusable blade electrode curved length 7 cm D01 model
- 138-152-115: reusable blade electrode length 16 cm E02 model
- 138-152-120: needle electrode 7 cm D03 model
- 138-152-122: curved needle electrode 7 cm D04 model
- 138-152-125: reusable needle electrode length 13 cm E01 model
- 138-152-130: ball electrode Ø 2 mm 6 cm D05 model
- 138-152-132: round curved electrode Ø 2 mm 6 cm D06 model
- 138-152-140: ball electrode Ø 3 mm 6 cm D07 model
- 138-152-142: curved ball electrode Ø 3 mm 5 cm D08 model
- 138-152-145: round electrode Ø 3 mm 14 cm E03 model
- 138-152-150: ball electrode Ø 4 mm 6 cm D09 model
- 138-152-152: round curved electrode Ø 4 mm 6 cm model D10
- 138-152-175-10: loop electrode 10×10 cm L.15 E06 model
- 138-152-190-13: loop electrode 20×13 cm L.15 E05 model
- 138-152-190-20: loop electrode 20×20 cm L.15 E07 model
- 138-152-195: 13 cm conisation electrode E08 model
- 138-CB462: Silicon wire for bipolar electrosurgery units 3mt
- 138-310-110-05: bipolar forceps 11.5 cm TIP 0.5mm
- 138-310-112-05: curved bipolar forceps 11.5 cm TIP 0.5mm
- 138-310-140-10: bipolar forceps 20 cm TIP 1 mm
- 138-310-140-20: bipolar forceps 20 cm TIP 2 mm
- 138-310-142-10: curved bipolar forceps 20cm TIP 1mm
- 138-310-142-20: curved bipolar forceps 20cm TIP 2 mm
- 138-310-180-10: angled bipolar forceps 20cm TIP 1 mm
- 138-310-180-20: angled bipolar forceps 20cm TIP 2 mm
- 138-310-182-10: angled curved bipolar forceps 20 cm TIP 1 mm
- 138-310-185-10: angled curved 20 cm TIP 2 mm
- 138-310-510: bipolar electrode 20cm
- 138-310-550: bipolar electrode 20cm
- 138-310-590: bipolar electrode 20cm
- 138-500500.L1:straight thin wire electrode length 5 cm (5 pcs)
- 138-500500.L1-L: straight thin wire electrode length 10 cm (5 pcs)
- 138-500500.L2:bent thin wire electrode length 5 cm (5 pcs)
- 138-500500.L2-L: bent thin wire electrode length 10 cm (5 pcs)
- 138-500500.L3: loop electrode Ø 4 mm length of 5 cm (5 pcs)
- 138-500500.L3-L: loop electrode Ø 4 mm and length 10 cm (5 pcs)
- 138-500500.L4: loop electrode Ø 8 mm length 5 cm (5 pcs)
- 138-500500.L4-L: loop electrode Ø 8 mm length 10 cm (5 pcs)
- 138-500500.L5: hook electrode length 5 cm (5 pcs)
- 138-500500.L5-L: hook electrode length 10 cm (5 pcs)
- 138-500500.L6: bent thick wire electrode 5 cm (5 pcs)
- 138-500500.L6-L: bent thick wire electrode 10 cm (5 pcs)
- 138-500500.L7: drop electrode length 5 cm (5 pcs)
- 138-500500.L7-l: drop electrode length 10 cm (5 pcs)
- 138-500500.L8: noose electrode length 5 cm (5 pcs)
- 138-500500.L8-L: noose electrode length 10 cm (5 pcs)
- 138-500500.L9: straight ball electrode Ø 3 mm 5 cm (5 pcs)
- 138-500500.L9-L: straight ball electrode Ø 3 mm length 10 cm
- 138-500500.L10: bent hook electrode length 5 cm (5 pcs)