Sprutpump SK-500II för 5 olika typer av sprutor

14400 kr

Quantity
Artikelnr: 55650 Kategorier: ,

Product description

Syringe pump supports 937- SK600II Ref .

    Is designed for use in hospitals and allows accurate and continuous intravenous infusion of fluid into patients.
    
For neonatal, pediatric and adult intensive care unit and operating room.

Features:

    Drug library with all the most used drugs .
    
Review of the historical record and the last memory configuration .
    
Change the flow rate during operation .
    
Manual and automatic bolus bolus .
    
Antibolo system to significantly reduce the bolus after the sudden release of the occlusion.
    
Microflow rate of 0.1 nmol / h bodyweight mode to meet the requirements for neonatal and pediatric patients.
    
Wireless data transmission to the monitoring system of the infusion (optional ) .

 Product appearance , parts and features:

The syringe pump SK- 500II is a single unit with an internal rechargeable battery .

The syringe pump SK- 500II has the following parts :

    Control system: the core of the entire system. Provides intelligent control and management of the whole system and processes the sensor signals . The system employs two unique chips that perform backup and monitor each other . If one of the SCM fails , the other issue a timely warning and cut power from the host computer to stop the pump and ensure patient safety .
    
Pump: supplying energy to the infusion. The feed motor drives a screw which in turn pushes the plunger in a syringe.
    
Monitoring system : a set of sensors , including displacement sensors (which measure the flow rate of the liquid) and pressure sensors (which measure the internal pressure of the syringe) .
    
Alarms: Audible and visible alarms . They attract the user’s attention and remind you about proper pump operation .
    
Input and display systems : the input device is used to set the parameters of the pump, and the flow velocity. The display shows the parameters and operational status .
    
Battery : The battery keeps the pump running when no AC power .

Battery:

    This syringe pump uses a rechargeable battery which ensures normal operation of the pump during patient transfers or interruptions of power supply in the hospital. The battery charges only when you connect the pump to an AC supply only when the pump turns on . The pump will run your battery in case of a sudden failure of power supply.
    
The battery can only supply power for the pump to operate normally for a specified period . The low battery alarm will sound at least 30 minutes before the battery runs out. During this period, the pump will continuously emit an alarm and display a reminder. The empty battery alarm will sound at least three minutes before the battery runs out. During this period , the pump will continuously issuing an urgent alarm , display a reminder and stop working.
    
The battery indicator light shows the battery status :
    
Indicates the status of the battery when disconnected the power supply . Green: the battery is high. Yellow : the battery is average. Red : the battery charge is low.
    
While charging , flashing green, yellow and red. When the battery is fully charged, solid green lights .
    
The battery life depends on how often you use and the operating environment . If used and maintained properly , the duration is 3 years . The duration may be lower if not used correctly. The battery should be replaced every three years .

Features SK- 500 :

    Precise control of flow rate.
    
Precise control of the infusion volume .
    
Good linear flow rate .
    
Completion Alarm , Syringe empty , Occlusion , Disconnection , System failure, motor error , memory error , empty battery , Low battery, Reminder, almost completion , AC Disconnect .

Technical Specifications:

Syringe type : 5, 10 , 20, 30 , 50 ml

Mode of operation:

1) Speed ​​mode flow velocity range : 0.1 to 1500 ml / h ( increase of 0.1 ml / h ), the maximum speed value depends on different syringes ; preset volume range : 0.0 – 999.9 ml

2 ) time mode , time range : 1-2000 min , preset volume range : 0.1 to 999.9 ml

3) Method of body weight, weight range : 0.1 to 300.0 kg of the drug limit : 0.1 to 999.9 mg, drug unit : mg / g, the dose limit : 0.1 – 1500.0 , the dosage unit : ug / kg / min or mg / kg / h , preset volume range : 0.1 to 999.9 ml

Cumulative injection volume : 0.1 – 999.9 ml

Accuracy: ± 3%

Range of flow rate:

    5 ml syringe 0.1 ml / h – 100 ml / h
    
10 ml syringe 0.1 ml / h – 200 ml / h
    
20 ml syringe 0.1 ml / h – 400 ml / h
    
30 ml syringe 0.1 ml / h – 600 ml / h
    
50 ml syringe 0.1 ml / h – 1500 ml / h

Increment: 0 . 1 m l / h

Bolus speed :

    5 ml syringe 100 ml / h ;
    
10ml syringe : 200 ml / h ;
    
Syringe 20 ml: 400 ml / h ;
    
30 ml syringe 400 – 600 ml / h adjustable;
    
50ml syringe : 600-1500 ml / h adjustable

MVA speed : 0,1 – 5.0 ml / h adjustable, 1 ml / h as Default

Drug library 40 drugs

Historical record : 1500 records ( operation status , the infusion information , alarms)

Saved syringe marks 15 marks
Display:

Display: LCD B / W 3.5 in.

Information : Operating mode , speed flow injection volume accumulated Syringe size , battery capacity , no bed , Indicator AC indicator, battery charge , Stop, Run, Bolo , MVA , Review syringe , etc. .

Display: Stop, Run, MVA
Alarm type:

Alarm Type : End, Near , Syringe empty , Syringe disconnected, occlusion , empty battery , Low battery, Reminder to run , No AC , Errors .

Pressure Range occlusion alarm : 3 levels : 70 kPa , 100 kPa , 130 kPa ( ± 30 kPa ) Low as Default
Battery:

Type: Lithium Polymer Battery

Operation time:

    Continuous operation of up to 4 hours at a flow rate of 5 ml / h battery is walking.
    
Continuous operation of up to 6 hours at a flow rate of 5 ml / h with optional battery .

Environment:

temperature:

    5-40 C to function ;
    
-20 – 50 C Storage

Air Pressure:

    86-106 kPa to run ;
    
50-106 kPa storage

humidity:

    20 % – 80 % to run ;
    
10% – 95% for storage

other :

Classification: Class II , Type BF

Dimension: 310 mm ( L ) × 125 mm ( D ) × 115 mm ( H )

Power supply: 100-240 VAC, 50/60 Hz

Waterproof level : IPX3