Product description
CPAP apnea device.
The device of continuous positive air pressure (CPAP) is designed only for the treatment of obstructive sleep apnea (OSA).
Actual treatment:
- The device provides a continuous steady pressure.
- The device maintains a constant pressure level during the breathing cycle.If you are prescribed the use of the ramp cycle, when it is on the air flow, you must enable restart button ramp ramp cycle (which reduces air flow pressure and then gradually increased over the period of time ).
- This will help you sleep more comfortably
Technical features:
Operating temperature Moisture level air pressure | 5 ~ 30 ºC ≤ 80 % without condensation Between 860 and 1060 hPa |
Transport temperature Moisture level air pressure | – 20 ~ 55ºC ≤ % 93 without condensation Between 500 and 1060 hPa |
Regulations | Safety requirements IEC 60601-1 medical equipment IEC 60601-1-2 Electromagnetic compatibility Treatment for sleep apnea breathing ISO 17510-1 |
Work mode | Continuous |
Energy consumption AC | 100-240 ACV. 50/60 Hz, 95 VA (max.) |
Type and grade of protection against electric shock | Class II, type BF |
Type and grade of protection against water penetration | IPX1 – Drop test – Vertical |
Automatic altitude compensation | a 0-750 m. level 0, a 751 – 1500 m. level 1, a 1501-2500 m. level 2 |
Noise level | < 30 dB, when the equipment is working in a pressure of 10hPa |
Work mode | CPAP |
Pressure range | 4 – 20 hPa (in increments of 0.5 hPa) |
Pressure stability | 4 – 20 hPa ± 1 hPa |
Air flow table:
Test pressure (hPa) | 4 | 8 | 12 | 16 | 20 |
Average pressure of the patient connection port (l / min.) | 70.1 | 73.6 | 75.9 | 73 | 73.4 |
Accessories included:
- Hand bag (with handle to use as shoulder strap)Air flow table:
- Filtre
- Tube
- Nose Mask
- Elastic harness to support mask
- Thermic humidifier
Thermic humidifier:
- The thermic humidifier with heating is designed only for use with CPAP/Auto CPAP o BPAP. do not use the thermic humidifier with any other equipment
- The humidifier moistens the air administered by CPAP / BPAP devices.
- The heated humidifier is used only for a single patient and should not be reused in another person. This prevents the risk of cross infection.
- The heated humidifier is designed for use with a patient whose upper airways are disabled.
Water capacity | 350 ml until mark |
Ambient operating temperature Moisture level air pressure | 5 ~ 30ºC ≤ 80 % without concentration Between 860 and 1060 hPa |
Ambient transport temperature Moisture level air pressure | – 20 ~ 55ºC ≤ % 93 without concentration Between 500 and 1060 hPa |
Regulations | IEC 60601-1 General safety requirements for medical equipment IEC 60601-1-2 Electromagnetic compatibility EN ISO 8185:1998 General requirements for humidification system |
Heater adjustments | 1 – 5 ( 104 – 149 ºF , 40 – 65 ºC ) |
AC energy consumption | 24 DCV , 1.0 A max |
Type and grade of protection against electric shock | Class II, type BF |
Type and grade of protection against water penetration | IPX1 – Drip test – Vertical |
Max working pressure | 30 hPa |
Pressure with humidifier | 60 LPM flow <0,5 hPa |
Maximum air output temperature. | < 40 ºC |
Humidity interval | 10 – 45 mg HO/L |
Optional accessories and spare parts:
- Ref. 869-FILTERCPAP: Filter for CPAP 869 devices
- Complete face mask for 869-CPAP and 869-AUTO-CPAP apnea
- Ref. 869-CPAPMASK-M: Size M
- Ref.869-CPAPMASK-L: Size L