Livsviktigt tecken kontrollapparat EKG, NIBP, SpO2, TEMP

13600 kr

Quantity

Product description

* This product is not available in the UK.

Vital signs monitor.

  • This monitor is a multi-functional instrument designed for monitoring the vital physiological signs of adult and pediatric patients (with optional pediatric accessories).
  • Allows recording and displaying real-time parameters, such as ECG, heart rate, non-invasive blood pressure, functional oxygen saturation, body temperature, and so on, allowing comprehensive analysis of patient’s physiological conditions.
  • This instrument is meant for hospitals and health care facilities.
  • It should be used by qualified professionals only.
  • This model does not include printer.

Features:

  • Blood pressure, SpO2 and pulse rate are displayed with large, bright, digital LEDs;
  • ECG waveform, SpO2, plethysmogram and system parameters are displayed on the colour LCD display;
  • Accurate NIBP measurement with hardware and software over-pressure protection;
  • The unique SpO2 measuring technique ensures sensitive and accurate SpO2, pulse rate and perfusion index measurement;
  • HR and SpO2 trend curve displayed for 12, 24 or 96 hours;
  • Up to 12000 groups of NIBP measurements (non volatile) can be stored and reviewed by list;
  • Up to 120-hour ECG waveform can be stored and recalled;
  • Audible & visible alarm with 3 levels of alarm events;
  • Nurse call output is available;
  • With tourniquet function;
  • NIBP measurement is applicable to adult, pediatric and neonate by patient selection (with optional pediatric accessories);

Structure:

The Vital Signs Monitor is a module designed product; it consists of ECG/TEMP module, NIBP module, SpO2 module, main control unit, display panel, and power supply block and the related accessories for ECG, NIBP, SpO2 and Temperature measurement.

  • ECG/TEMP module measures ECG signal and detects heart rate with ECG lead wires and electrodes, it also measures temperature with temperature probe.
  • The SpO2 module detects and calculates pulse rate and oxygen saturation (SpO2), and provides plethysmogram and perfusion index as well.
  • The NIBP module performs the measurement of blood pressure by non-invasive way of oscillometric technology, including the diastolic, systolic and mean arterial pressure. The cuffs are designed for adult, pediatric and neonate respectively.
  • The main control unit includes the LED and LCD display, keyboard for data input and storage and power socket.

Technical specifications:

ECG Monitoring:

1. Input signals range in amplitude: ± (0.5 mVp ~ 5 mVp)

2. Heart rate display range: 15 bpm ~ 350 bpm

3. Heart rate display accuracy: ± 1% or ± 2 bpm, whichever is greater.

4. Heart rate averaging: Averages the recent eight beats having RR intervals falling within the acceptable
limits.

5. Heart rate alarm delay time: ≤ 10s

6. Response time to change in heart rate:

  • Change from 80 bpm to 120 bpm: < 8 sec
  • Change from 80 bpm to 40 bpm: < 8 sec

7. Tall T-wave rejection: Rejects all T-wave less than or equal to 120% of 1mV QRS.

8. Sensitivity selection:

  • ×1/ 4, 2.5 mm/mV tolerance: ± 5%
  • ×1/ 2.5 mm/mV tolerance: ± 5%
  • ×1, 10 mm/mV tolerance: ± 5%
  • ×2, 20 mm/mV tolerance: ± 5%

9. Sweeping speed: 25 mm/s tolerance: ±10%

10. ECG noise level: ≤ 30µV p-p.

11. ECG input loop current: ≤ 0.1µA

12. Differential input impedance: ≥ 5MΩ

13. Common-mode rejection ratio (CMRR): ≥105dB

14. Time constant: ≥ 0.3s

15. Frequency response: 0.67 Hz~40 Hz ( +0. 4db,-3.0db)

TEMP Monitoring:

1. TEMP measuring range: 21.0 ºC ~ 50.0 ºC

2. TEMP measuring accuracy: not greater than 0.2 ºC for TEMP measuring range from 25.0 ºC to 45.0 ºC

3. TEMP response time: ≤150s

NIBP Monitoring:

1. Measuring method: Oscillometric Technique

2. Pneumatic pressure measuring range: 0 mmHg~300 mmHg

3. Accuracy of pressure measurement: ±3 mmHg

4. Cuff inflation time: <10 seconds (typical adult cuff)

5. Measurement time on the average: < 90 seconds

6. Air release time while the measurement is cancelled: =2 seconds (typical adult cuff)

7. Initial cuff inflation pressure:

  • Adult: 175 mmHg
  • Infant: 135 mmHg (accesories not included).
  • Neonate: 65 mmHg (accesories not included).

8. Overpressure protection limit:

  • Adult: = 300 mmHg
  • Infant: = 240 mmHg (accesories not included).
  • Neonate: = 150 mm (accesories not included).

9. NIBP measurement range:

Pressure (unit) Adult Infant Neonate
SYS mmHg 40~255 40~200 40~135
MAP mmHg 20~215 20~165 20~110
DIA mmHg 10~195 10~150 10~95

10. NIBP accuracy:

  • Maximal mean difference: ±5 mmHg
  • Maximal standard deviation: 8 mmHg
  • Measurement mode: Manual, Auto, STAT

SpO2 Monitoring:

1. Transducer: dual-wavelength LED:

  • Wavelength: Red light: 660 nm, Infrared light: 905 nm.
  • Maximal optical output power: less than 2mW maximum average.

2. SpO2 measuring range: 35%~100%

3. SpO2 measuring accuracy: Arms is not greater than 3% for SpO2 range from 70% to 100%

*NOTE: Arms accuracy is defined as root-mean-square value of deviation according to ISO 9919

4. Low perfusion performance: the declared accuracy is attained when the pulse amplitude modulation ratio is as low as 0.4%.

Pulse Rate monitoring:

1. Pulse rate measuring range: 30 bpm~240 bpm

2. Pulse rate measuring accuracy: ±2 bpm or ±2%, whichever is greater.

Data Recording:

1. Sensitivity selection tolerance: ±5%

2. Recording speed: 25 mm/s

3. Recording speed accuracy: ±10%

4. Hysteresis: ≤0.5 mm

5. Frequency response: Monitoring mode: 0.5/40 Hz

6. Time constant: Monitoring mode: ≥ 0.3s

Other technical specifications:

1. AC power supply voltage: 100 ~ 240 VAC

2. AC power frequency: 50/60 Hz

3. Fuse specification: T3.15 AL/250V Φ5Í20 mm.

4. Internal power supply: 12 VDC (rechargeable).

5. Battery specification: 12V 2.3AH (sealed lead-acid battery).

Operating environment:

  • Working environment

    • Ambient temperature range: 5 ºC ~ 40 ºC
    • Relative humidity: 30 ~ 80%
    • Atmospheric pressure: 70 kPa ~106 kPa
  • Transport and storage environment.

    • Ambient temperature range: -20°C ~ 60°C
    • Relative humidity: 10 ~ 95%
    • Atmospheric pressure: 50.0 kPa ~107.4 kPa

Accessories

  • ECG cable with lead wire
  • ECG electrodes (25 pieces)
  • Adult NIBP cuff (25 cm-35 cm)
  • Adult SpO2 probe
  • Temperature probe
  • Power cord
  • Grounding wire
  • User manual

Optional accessories and spare parts:

  • Ref. 902-PC900BAT:  Battery for 902-PC900 monitor.