Extern semiautomatisk defibrillator AED-2100 Språk portugisiska

28600 kr

Quantity

Product description

SEMI-AUTOMATIC EXTERNAL DEFIBRILLATOR
CARDIOLIFE-2100K AED

Defibrillator

  • Waveform: Biphasic truncated exponential constant voltage.
  • Output power range: 50, 70, 100, 150, 200 J (50 ohm).
  • Sequence output power:

    • 150 J – 200 J – 200 J for adults.
    • 50 J – 70 J – 70 J for children.
  • Cycle Time Analyzer-a-SHOCK:
  • Less than 8 seconds (when using a new battery).
  • Cycle time from the end of CPR to SHOCK:
  • Less than 8 seconds (when using a new battery).
  • Internal automatic discharge: The stored energy is discharged in the following conditions:

    • 30 seconds have passed after the SHOCK BUTTON started flashing.
    • Electrode was disconnected from the AED or the patient.
    • The power is off.
    • ECG appears normal.
    • During the self-diagnosis.
    • The battery is removed.
       

Battery

  • Output voltage: 30 V, 3 V.
  • Life (standby): 2 years.
  • Shelf life (storage device separately): 6 years from date of manufacture.
  • Capacity: With a new battery at an ambient temperature of 20 ° C, approximately over 70 downloads or more than 120 minutes of continuous operation.
     

Self-diagnosis

  • Daily check: Battery, electrodes, temperature, internal circuit.
  • Monthly check: high voltage capacitor with maximum energy power and off, battery, electrodes, temperature, internal circuit.
  • If the instrument is turned on and off: Battery, pads, internal circuitry, self history.
  • When placing the battery: Battery, electrodes, temperature, internal circuit, charge and discharge energy.
  • If abnormalities are detected during self-diagnosis, the status indicator turns red and an alarm sounds.
     

Analysis of arrhythmia

Precision:
90% or more for VF (sensitivity).
75% or more for VT (sensitivity).
95% or more for non-shockable waveforms (specificity).
 

Data storage

Total storage: 90 minutes.
Up to 3 cases rescue data (max. 30 min / data).
 

Indicators

  • Status Indicator: Green (normal) or red (abnormal).
  • Shock button: Flashes when the shock is ready.
  • Indicator electrode position: Flashes when the electrodes are not in contact with the patient.
  • Electrode testing indicator: Lights in the following cases: If the electrodes are not connected to the AED, if electrodes are expired, if the electrodes are not suitable for the AED-2100K
  • Battery status indicator:

    • 100%: 4 green lights
    • 75%: 3 green Lights
    • 50%: 2 green lights
    • 25%: 1 green light
    • 0%: red lights
  • Child mode LED: Lights if you switch adult mode to child mode.
     

Dimensions and weight 

Dimensions: 250 wide. × 315 deep. × 100 high. (mm).
Weight: 2.5 kg (including battery and electrodes).
 

Communication

  • Interface: Bluetooth (version 2.0. + EDR).
  • Maximum Output: 4 dBm.
  • Communication distance: about 10 m if no obstructions.
  • You must register in accordance with radio legislation to use Bluetooth in each country.
  • You can transfer the following data to a PC with Bluetooth interface.

    • Device-information (model, serial number, version, etc.).
    • Rescue-Data (waveform and ECG events, etc.)
    • Self-diagnosis record.
    • Battery information (model, serial number, version, number of loads completed, operating time, operating days in standby, remaining battery capacity).
  • The following data can be transferred to the AED.

    • Time
    • Configuration Information
    • Software-Version
       

Environmental conditions

  • Operation and standby mode (the battery is inserted and the power off) or shipping for 1 week or longer:

    • Temperature 0 to 50 ° C.
    • Humidity = 5 to 95% RH (non-condensing).
    • Atmospheric pressure of 570-1030 hPa.
  • Shipping conditions (less than 1 week):

    • Temperature -30 to 65 ° C.
    • Humidity: 5 to 95% RH (non-condensing).
    • Atmospheric pressure 570-1030 hPa.
  • Input Protection: CEI60529: 2001, IP55.
  • Vibration:

    • MIL-STD-810F 514.5 Category 4.
    • MIL-STD-810F 514.5 Category 9.
  • Shock:

    • IEC 60068-2-27: 1987 50G.
    • IEC 60068-2-29: 1987 10G.
  • Fall: IEC 60068-2-32: 1975. Amendment 2: 1990 1.2 m.

Spare parts and optional accessories

  • Ref. 274-MX216A: Battery 2 years life
  • Ref. 274-MX217A: Battery 4 years life
  • Ref. 274-MH324A: Electrodes Adult-Pediatric