• Fri frakt på beställningar över 2000 kr inkl. moms.
  • track-32Trygga betalningar. Faktura- och kortköp.
  • track-32Bli förmånskund och spara pengar (endast företag).
  • track-32Support på 08-6844 22 44 eller info@nordmed.se
Image Alt

Butik

  /    /  Elektrostimulatorer, GLOBUS El-stimulatorer, Medicinsk teknik  /  Elektrostimulator med 4 kanaler GENESY 3000, 423 program

Elektrostimulator med 4 kanaler GENESY 3000, 423 program

16000 kr

Quantity

Product description

  • The Globus electro meets Genesy 3000 Globus the best technology has improved in recent years to create a professional within the electro-medical rehabilitation and physiotherapy.
  • Its dimensions and ergonomic design make it a tool that can be used both as a fixed station or portable unit. Equipped with a wide range of programs to offer applications in the treatment of pain, to promote the rejuvenation of the tissues or for treatment of neuromuscular dysfunction among other important applications.
  • Genesy 3000 has been designed to achieve a more rapid and effective rehabilitation of people with injuries and has specific programs to address post-traumatic phase, intervening in the recovery of individuals who have been subjected to surgery.
60 pre-set programs:
  • EASY PROGRAM: Get a faster schedule.
  • MY TRAINER: displays all the images of the positioning of the electrodes directly on the display.
  • STIM FIT: Modify the program of contraction during stimulation.
  • FAST MENU: Get a menu navigation faster.
  • STIM LOCK: allows the therapist to the patient only used on programs that have been prescribed.
  • WORK TIME: displays the time using the cash machine by all users.
  • BACKLIT GRAPHIC DISPLAY
  • DUAL STIM 2 +2: possible to use two different programs at once.
  • AUTO STIM, the only stimulus that gets used a program in automatic mode without manual intervention on their regulation.
  • SYNCROSTIM: by pressing a single button you can increase the intensity of the 4 channels simultaneously.
  • MULTI-USER: Get share among multiple users while maintaining electro memorized the respective programs, preferences and applications.
  • MEMO FUNCTION: able to create a library of custom programs.
  • LAST 10: saves the last program run, so it is ready to be used quickly and easily.
Rehabilitation:
  • Rehabilitation programs use current EMS in order to restore normal muscular efficiency in the treatment of recovery from injury.
  • Muscle stimulation is also a useful tool in some situations where the normal neuromuscular function is compromised.
  • Atrophy Recovery
  • Motor point pen
  • Remusculación
  • Strengthening
  • Mobilization
  • Agonist / Antagonist
  • Elasticity lig. Cross
  • Achilles tendon elasticity
  • Elastic ligaments sup members.
  • Upper limb hemiplegia
  • Lower limb hemiplegia
  • Bladder instability
  • Mixed Incontinence
  • Stress incontinence
  • Paraplegia (injury prevention)
  • Upper limb spasticity
  • Spasticity in lower limbs
  • Hip
TENS:
  • Transcutaneous electrical stimulation (TENS) is an analgesic stimulation is performed with pulses that reach the peripheral nervous system via electrodes placed on the treated area. Was carried out with symmetrical biphasic pulses and frequencies that can vary from 8 to 200 Hz
  • Tens endorphin
  • Bruising
  • Contractures
  • Sciatica
  • Antistress
  • Back pain
  • Neuralgia cervicobrachial
  • Cervical
  • Scapular humeral periarthritis
  • Epicondylitis
  • Nausea
  • Carpal Tunnel
  • Osteoarthritis of the hip
  • Patellar chondritis
  • Period pains
  • Severe menstrual pain
  • Tens acute pain Analgesic
  • Analgesic Tens chronic pain
  • Tens Modulated
  • Deep Spill
  • Trapezius Algia
  • Pain in hips
  • Knee pain
  • Pain in the ankle
  • Tens antal. of antiacomodación
  • Fracture Pain
  • Chronic pain
  • Fractured ribs
  • Reflex sympathetic dystrophy
  • Pain in fingers
  • Periostitis
  • Cervical Rizopatía
  • Phantom limb 1-2
  • Spinal compression
MCR:
  • MENS flows using current whose intensity is between 10 and 500 uA (microamps = one millionth of an ampere). MENS therapy provides two distinct stages, the first is aimed at decreasing the pain sensation perceived by the patient, while the second promotes protein synthesis and ATP accelerate reparative processes of the tissues.
  • Epicondylitis
  • Scapular humeral periarthritis
  • Contractures
  • Muscle Stretching
  • Muscle tear
  • Restoring muscle energy
  • Contusion
  • Rheumatoid Arthritis
  • Edema
  • Herpes Zoster
  • Hematoma
  • Ischemic skin ulcers
  • Sciatica
  • Femoral neuralgia
  • Back pain
  • Herniated disc and lumbar spondylosis
  • Brachial Neuralgia
  • Stiff neck
  • Hemicrania
  • Pain in the neck by ”Whiplash”
  • Cervical spondylosis
  • Distortion of the shoulder
  • Carpal Tunnel Syndrome
  • Hand arthritis
  • Fractured finger
  • Distortion of the knee
  • Inflammation of the patellar tendon
  • Osteoarthritis of the Knee
  • Ankle distortion
  • Inflammation of the Achilles tendon
  • Effect microlifting bust
  • Effect neckline microlifting
  • Effect microlifting face
  • Elasticity of facial skin
Interferential Current:
  • This particular type of flow creates an interference zone within the tissue at the point where they cross the fields. Sinusoidal alternating current is a medium frequency (2500 Hz – 4000 Hz – 10000 Hz), amplitude modulated, characterized by a high capacity for tissue penetration and an excellent tolerability, even in particularly sensitive patients.
  • Constant (for painful tendon and muscle disorders)
  • Sweep from 80 to 100 Hz (for painful tendon and muscle disorders) in the acute phase
  • Sweep 500-100 Hz (for painful tendon and muscle disorders in the acute phase and in the presence of inflammation)
  • Sweep 5 to 20 Hz (which requires painful manifestations reabsorption of edema (pump effect)
  • Multi freq (reabsorption of edema in the presence of acute pain)
  • Sweep 5 to 50 Hz (for muscle diseases in need of re-absorption of edema)
  • Sweep 50-100 Hz (acute and chronic muscle pain)
  • LP (used as an alternative to diadynamic LP)
  • CP (used as an alternative to diadynamic LP)
  • COST, LP, CP (Association of previous programs)
  • AMF (Suitable for large areas of pain)
  • Degenerative osteoarthritis of the knee
  • Acromial bursitis
  • Miotensiva headache.
  • Acute Cervicobraquialgía
  • Coxarthrosis
  • Distortion of the knee
  • Acute neck pain
  • Acute back pain
  • Epicondylitis
  • CLBP
  • Scapular humeral periarthritis
  • Contractures
  • Distortion of the shoulder
  • Ankle distortion
Kotz currents:
  • Used in medical field because it produces good muscle recruitment and exerts a more profound excitomotoras other streams. The effect of Kotz current develops in the deeper layers of muscles, as opposed to a lower skin resistance to this type of current.
  • L5 suffering residual hypotrophy
  • Rectus quadriceps hypotrophy
  • Post-traumatic hypotrophy ischiocrural
  • Deltoid muscle hypotrophy post-traumatic
  • Triceps hypotrophy
  • Hypotrophy vastus medialis
  • CLBP
  • Strength training after meniscopatia
  • Vertebral Osteoporosis
  • Flatfoot
  • Lumbar vertebral fractures leg
  • Quadriceps strength
  • Reactivation advanced muscular
  • Hypokinetic syndrome
  • Metatarsalgia
  • Reactivation of the gluteus medius
  • Serratus muscle strengthening
  • Isometric quadriceps strengthening
  • Peroneal muscle strengthening
  • Heating
  • Scoliosis
  • Muscle toning
  • Hyperkyphosis cage.
  • Muscle hypertrophy
  • Dorsal paravertebral muscle hypotrophy.
  • Muscle training
  • Hypotrophy inveterate Coxarthrosis gluteal
  • Desfatigamiento
  • Deficit buttocks by suffering
  • Colles Fracture – reactivation flexor
Iontophoresis:
  • The program acts iontophoresis drug transporting substances inside the tissue to an electric current through continuous unidirectional.
  • Ions of the medicinal substance is transported inside the body through the skin areas to low resistance opposed to the current, thus reaching the cell membranes.
Denervated:
  • The stimulation of a denervated muscle differs from that of healthy muscle by the fact that the activation of muscle fibers requires particular currents.
  • Faced with a traumatic injury of peripheral nerves, the measure of chronaxies to be established whether denervation is limited, partial or total.
  • 1a – Rectangular Pulse shape 1
  • 1b – 2 Rectangular Pulse shape
  • 1c – 3 Rectangular Pulse shape
  • 2a – 1 Triangular Pulse shape
  • 2b – 2 Triangular Pulse shape
  • 2c – 3 Triangular Pulse shape
  • 3a – 1 Trapezoidal Pulse shape
  • 3b – 2 Trapezoidal Pulse shape
  • 3c – 3 Trapezoidal Pulse shape
Beauty:
  • The 3000 incorporates Genesy programs designed for body care and beauty: There are numerous treatments such as drainage, modeling, lipolysis, facial toning, cellulite action, which can be applied individually or in combination with each other. The effect of stimulation is exalted when combining multiple treatments together in each session: each phase of treatment works with distinct and specific ways (eg, surface-drainage massage, deep tissue massage-action anti-cellulite, toning), acting in synergy yes, provide the best and longest lasting results.
  • Drainage Bio-press
  • Lipolysis 1-2
  • Relaxing Massage
  • Toning massage 1-2
  • Energetic massage 1-2
  • Connective tissue massage 1-2
  • Drainage postpartum
  • Lipolysis postpartum
  • Firmness postpartum
  • Bust Firming
  • Modeling bust
  • Swollen Arm
  • Capillarization face
  • Face lifting effect
  • Arterial insufficiency
  • Venous insufficiency
  • Definition 1-2
  • Line 1-2
  • Vascularization 1-2
  • This program for men and women
Sports
  • Genesy 3000 offers a range of sports training programs adequate to meet the preparedness needs of top athletes in major sports.
  • Heating
  • Precompetition Warming
  • Active recovery
  • Maximum Force 1-2
  • Resistant Force 1-2
  • Explosive Force 1-2
  • Endurance 1-2
  • Reactivity
  • Postcompetición Recovery
  • Descontracturación
  • Hypertrophy
  • Dynamic Work 1-2
FITNESS:
  • Firmness
  • Bio-press firmly
  • Modeling
  • Modeling Bio-press
  • Toning
  • Increase of mass
  • Body Sculpting
  • Definition
  • Jogging
  • Anaerobic
  • Muscle starter
  • Aerobic
  • Preventing cramps
TECHNICAL FEATURES:
  • Channels: 4 independent channels (8 electrodes)
  • Frequency: 0.3 – 150 Hz
  • Power: 120 mA per channel
  • Pulse width: 45 to 450 ms
  • Waveform: Square wave, biphasic, symmetrical, compensated
  • Power: Power supply 18V – 3.3A
  • Battery: 12 V, 2000 mAh
  • Compliance: Conforms to the ISO 9001, EN 46001 for medical equipment. Certificates MDD (Medical Devices Directive)
  • Dimensions: A = 17 x L = 21 x H = 6 cm
  • Weight: 500 gr
Standart setting:
  • 1 Bag
  • 1 Electro
  • 4 Cables to connect the electrodes
  • 1 Battery Charger
  • 4 self-adhesive electrodes 50 x 50
  • 4 50 x 90 self-adhesive electrodes
  • 1 electro Instruction Manual
OPTIONAL ACCESSORIES
  • 646-G1156: Pencil for motor points.
  • 646-G0136: Electrodes Autoadhesivos.4 delicado.PLATINUM uds.Extra 50×50
  • 646-G0137: Electrodes Autoadhesivos.4 pc. Extra 50×90 delicado.PLATINUM
  • 646-G0458: delicado.PLATINUM salida.Extra Electrodos.2uds.Rectangulares.Doble 2salidas
  • 646-G0464: self-adhesive electrodes. 4 pcs. 50×50. PLUS 50×50
  • 646-G0465: self-adhesive electrodes. 4 pcs. 50×90. PLUS 50×90
  • 646-G0448: self-adhesive electrodes. 2 pcs. Rectangular. Dual output. SAL PLUS 2
  • 646-G0466: self-adhesive electrodes. 4 pcs. Squares. PREMIUM SQUARE.
  • 646-G0467: self-adhesive electrodes. 4 pcs. Rectangular. PREMIUM SQUARE
  • 646-G0871: self-adhesive electrodes for the face. 4 pcs. 26 mm
  • 646-G0451: self-adhesive electrodes for the face. 4 pcs. 32 mm
  • 646-G0488: Electrodes Belt Kit + beauty treatments. FAST BODY KIT.
  • 646-G0487: abdominal belt electrode for the treatment of abdomen, buttocks and back. FAST BAND.
  • 646-G0489: Electrodes for aesthetic treatments. PAD FAST.
  • 646-G0885: + carbon electrode rectangular pocket. 60×85. BIG IONOPHORESIS
  • 646-G1210: pocket square. 50×50. IONOPHORESIS MEDIUM.
  • 646-G0155: rectangular pocket. 60×85. IONOPHORESIS BIG.
  • 646-G0461: Subway electrode conductive silicone.
  • 646-G0463: Kit 6 conductive silicon electrodes.
  • 646-G0453: 4 electrodes buff ionophoresis. 80×120.
  • 646-G0964: 5 electrodes buff ionophoresis. 80×120. Blister.
  • 646-G0452: 4 electrodes buff ionophoresis. 80×60.
  • 646-G0479: Kit conveyor bands for thighs.
  • 646-G0480: Kit TOP FITNESS conveyor bands.
  • 646-G0650: 4 electrodes 50×50 with CLIP.
  • 646-G0651: 5 electrodes 50×90 with CLIP.
  • 646-G1309: Handle G-Press to microwaves.
  • 646-G1188: Patient monkey vaginal probe.
  • 646-G0757: Patient monkey anal probe.